20-45 Minute Fire Protective Glazing Directional Without Hose Stream
This San Francisco school selected SuperLite I-XL to replace unsafe traditional wired glass, in order to benefit from its partial radiant heat protection and high impact resistance. The use of SuperLite I-XL ensures that students can safely pass through the corridors on a normal daily basis and during an emergency such as an earthquake or fire.
Please request a copy of our SuperLite I-XL Technical Bulletin to learn how your next project can benefit as well.
Product Advantages
Patented specialty tempered glazing tested without hose stream, that provides partial radiant heat protection not available with ceramics.
Accepted by the GSA and AHJ’s across the country as a safe and value added alternative to traditional unsafe wired glass and expensive ceramics.
Meets the highest human impact safety requirements.
Approved for 20 minute applications without limitations.
Received a General Approval from the City and County of Los Angeles (RR25655).
Regularly specified for use in urban-wildfire exterior applications, and perfect for property line requirements.
Available in specialty architectural make-ups.
Lifetime manufacturer’s warranty.
USA manufactured for fast delivery and competitive pricing.
Fire Rating
Application
Max. CV Area
Max. CV Width
Max. CV Height
Stops
20 minutes
Wood
Steel Doors
3,341 in.² (2.16 m²)
35-1/8 in. (0.89 m)
95-1/8 in. (2.42 m)
5/8 in. (16 mm)
20 minutes
Steel Sidelites
Windows
Transoms
5,760 in.² (3.72 m²)
96 in. (2.44 m)
96 in. (2.44 m)
5/8 in. (16 mm)
45 minutes*
Wood
Steel Doors
3,341 in.² (2.16 m²)
35-1/8 in. (0.89 m)
95-1/8 in. (2.42 m)
5/8 in. (16 mm)
45 minutes*
Steel Sidelites
Windows
Transoms
5,760 in.² (3.72 m²)
96 in. (2.44 m)
96 in. (2.44 m)
5/8 in. (16 mm)
* Please see details for limitations.
Specifications
Thickness:
Weight:
Fire Rating:
Impact Safety Rating:
Solar Heat Gain Coefficient:
Sound Transmission Rating:
1/4 in. (6 mm)
3.0 lbs./sq.ft. (15 kg/m²)
20-45 minutes without hose stream
CPSC 16 CFR 1201 Cat. I and II
0.70 SHGC
STC 28
Certifications
INTERTEK TESTED AND CERTIFIED
SuperLite I-XL is listed and labeled by Intertek and Underwriters Laboratories, nationally recognized testing laboratories approved by OSHA. Requires AHJ approval for 45 minute applications because this is a directional product that is tested without hose stream. Please visit www.safti.com/AHJ for more information.
Approvals
UL 9, UL 10B, UL 10C, NFPA 80, NFPA 252, NFPA 257, ASTM E152, ASTM E163, ASTM E2074, ASTM E2010-01, CPSC 16 CFR 1201 Cat. II., ANSI Z97.1
SuperLite I-XL
Description
20-45 Minute Fire Protective Glazing Directional Without Hose Stream
This San Francisco school selected SuperLite I-XL to replace unsafe traditional wired glass, in order to benefit from its partial radiant heat protection and high impact resistance. The use of SuperLite I-XL ensures that students can safely pass through the corridors on a normal daily basis and during an emergency such as an earthquake or fire.
Please request a copy of our SuperLite I-XL Technical Bulletin to learn how your next project can benefit as well.
Product Advantages
Steel Doors
Windows
Transoms
Steel Doors
Windows
Transoms
* Please see details for limitations.
Specifications
Certifications
SuperLite I-XL is listed and labeled by Intertek and Underwriters Laboratories, nationally recognized testing laboratories approved by OSHA. Requires AHJ approval for 45 minute applications because this is a directional product that is tested without hose stream. Please visit www.safti.com/AHJ for more information.
Approvals
Additional Product Advantages
Related products
SuperClear 45-HS
SuperClear 45-HS-LI
SuperLite I-XL IGU